Item #877019

Paneltronics Load Shedding Power Management System - 861-001

00 Review
$443.99
Want an email once available?
Buy with

Image of : Paneltronics Load Shedding Power Management System - 861-001 Paneltronics Load Shedding Power Management System - 861-001 Item # 877019

Description

Paneltronics 861-001 Load Shedding System is a marine quality, single 120V AC, 30 amp power management system that eliminates nuisance tripping of shore main, generator main, and branch circuit breakers by momentarily shedding and restoring loads.

Features:

  • Designed for use with marine electrical systems with single 120V AC 30 amp or 50 amp shore cord and single 120V AC generators rated from 4KW to 9KW
  • Automatically sheds up to (3) loads to limit total current draw to 30 amps from 120V, 30 amp shore cords; 50 amps from 120V, 50 amp shore cords; and 30 to 75 amps (field adjustable) from generators
  • Draw from shore power to below 30 amps
  • Generator current draw from 30 to 75 amps
  • Automatically restores power to shed loads when total load current drops below 30 amps for 120V, 30 amp shore cords; 50 amps for 120V, 50 amp shore cords; or 30 to 75 amps (field adjustable) for generators
  • Simple two component power management system (control module and display panel) is easily integrated into new or existing marine electrical power distribution systems
  • Control Module mounts inside or in close proximity to the vessel's AC main distribution panel (MDP)
  • Display Panel - Surface mounted, and can be located up to 100 feet from the Control Module

Specifications:

  • Input Voltage (Supply): 9 - 16V DC
  • Power Consumption: 4W AC / 5W DC
  • Input Voltage (Control): 110 - 130V AC 60Hz (Not recommended for use with inverters)
  • Number of Load Shed Circuits: 3
  • Shore Main Load Shed Threshold: 31 Amps (25 ms max)
  • Generator Main Load Shed Threshold: Field: adjustable 30 to 75 amps (25 ms max)
  • Maximum Load Current per Circuit: 30.0 Amps (resistive), 10.8 amps (inductive)
  • Maximum Air Conditioner Load: 12K BTU per circuit
  • Load Reset Time After Load Shed Event: 10 Seconds / 2 minutes (air conditioners)
  • (3) Load LEDs indicate load status
  • (2) LED digital display indicates total line current & last load shed current
  • (2) Source LEDs indicate shore or generator power
  • (2) Current transformers monitor shore or generator line current
  • Operating Temperature: 13°F (-25°C) to 122°F (50°C)

Dimensions:

  • 861-002 Display Panel: 4.9" L x 2.6" H x 0.9" D (124.46mm L x 66.04mm H x 22.86mm D)
  • 861-003 Control Module: 9.4" L x 5.2" H x 3.2" D (238.76mm L x 132.09mm H x 81.28mm D)
  • Current Transformers: 0.85" ID and 1.37" OD ( 21.59mm ID and 34.80mm OD )

Installation Instructions

Part Numbers for Paneltronics Load Shedding Power Management System - 861-001

Related Categories

Related Categories

Reviews

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 4.16ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;

Questions

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 4.8ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;