Cart   null      null
Track Orders
Customer Service
My Account
Logo linked to Defender Homepage
 Call or email to speak with our in-house knowledgeable staff.
Phone: 800-628-8225 | Int'l.: 860-701-3400 | Email: Contact Us
Marvair CR330 Condensation Removal Kit
Marvair CR330 Condensation Removal Kit
Marvair CR330 Condensation Removal Kit
Marvair CR330 Condensation Removal Kit
Marvair CR330 Condensation Removal Kit
Marvair CR330 Condensation Removal Kit
Marvair CR330 Condensation Removal Kit
Marvair CR330 Condensation Removal Kit
Marvair CR330 Condensation Removal Kit

Marvair CR330 Condensation Removal Kit

  • Removes Condensation and Discharges Overboard
  • Condensate Pumped Overboard when the Air Conditioner's Circulation Pump Runs
  • A Separate Condensate Pump is Not Required
  • Item #: 
    901639
    Brand: 
    Dometic
    Model #: 

    225600036

    Packaged Weight: 
    3.00 Lbs.
    List Price: 
    $400.00
    Our Price:
    $339.99
    901639 Dometic Marvair CR330 Condensation Removal Kit 225600036

    The Marvair CR330 removes the condensate water produced during the cooling cycle of your Marvair reverse-cycle air conditioner and discharges the condensate into the air conditioner's outlet water line

    Features:

    • The condensate is pumped overboard any time the air conditioner's circulation pump is working and sufficient condensate is in the condensate pan of your Marvair unit
    • By operating on the Venturi effect, a separate condensate pump is not required
    • A water filter/strainer, a reducer and a check valve are also provided and must be installed with the CR330
    • The filter prevents debris from entering the CR330 and obstructing the water flow
    • The check valve allows the condensate to flow in only one direction
    • The flow rate, measured at the air conditioner, must be at least 1.0 GPM (3.8 LPM) but no more than 4.6 GPM (17.4 LPM)
      • Flow rates less than 1.0 GPM (3.8 LPM) may result in improper removal of the condensate
      • Flow rates greater than 4.6 GPM (17.4 LPM) may result in a restriction of water flow to the air conditioner
      • Always refer to the air conditioner's Owner's manual or Product Data Sheet to determine the correct water flow for proper operation of the Marvair air conditioner
    • Installation:
      • The CR330 is installed into the outlet water line of the Marvair air conditioner
      • The discharge water flows through the CR330 to the overboard thru hull fitting
      • Condensate from the drain pan flows into the CR330 and is pulled overboard by the discharge water from the air conditioner
      • Included in the installation materials are 1/4” clear tubing and 5/8” clear tubing
      • Various lengths of this tubing must be cut to connect the components
      • To optimize the performance of the system, be sure to follow the recommendations for the lengths of tubing
      • Locate the outlet (discharge) water line on your Marvair air conditioner
        • Follow the water line, looking for a suitable place to install the CR330

    Diagram Parts List: (See Image Below)

    Number on Drawing
    Quantity
    Description
    12
    1
    CR330 condensate remover
    5
    1
    Strainer/filter with ½” FPT connections
    10
    1
    1/4” x 1/4” Check valve
    4
    1
    5/8” Barb x 1/2” FPT coupling
    3
    3
    Stainless Steel screw type hose clamp for 5/8” tubing
    7
    4
    Stainless Steel screw type hose clamp for 1/4” tubing
    8
    1
    2-1/2" x 1/4” ID clear tubing.
    11
    1
    7 ft x 1/4” ID clear tubing.
    1
    1
    1 ft x 5/8” ID clear tubing
    6
    1
    1/4” barb x 1/2” MPT adapter
    2
    1
    Hold down clamp for 5/8” tubing
    9
    2
    Hold down strap for 1/4” tubing
    13
    2
    Hold down strap for the CR330
    14
    1
    5/8” barb x 1/2” MPT fitting

    Click Here for an Installation Guide for this Product

    Marvair CR330 Condensation Removal Kit
    339.99
    Status:  null In Stock

    The Marvair CR330 removes the condensate water produced during the cooling cycle of your Marvair reverse-cycle air conditioner and discharges the condensate into the air conditioner's outlet water line

    Features:

    • The condensate is pumped overboard any time the air conditioner's circulation pump is working and sufficient condensate is in the condensate pan of your Marvair unit
    • By operating on the Venturi effect, a separate condensate pump is not required
    • A water filter/strainer, a reducer and a check valve are also provided and must be installed with the CR330
    • The filter prevents debris from entering the CR330 and obstructing the water flow
    • The check valve allows the condensate to flow in only one direction
    • The flow rate, measured at the air conditioner, must be at least 1.0 GPM (3.8 LPM) but no more than 4.6 GPM (17.4 LPM)
      • Flow rates less than 1.0 GPM (3.8 LPM) may result in improper removal of the condensate
      • Flow rates greater than 4.6 GPM (17.4 LPM) may result in a restriction of water flow to the air conditioner
      • Always refer to the air conditioner's Owner's manual or Product Data Sheet to determine the correct water flow for proper operation of the Marvair air conditioner
    • Installation:
      • The CR330 is installed into the outlet water line of the Marvair air conditioner
      • The discharge water flows through the CR330 to the overboard thru hull fitting
      • Condensate from the drain pan flows into the CR330 and is pulled overboard by the discharge water from the air conditioner
      • Included in the installation materials are 1/4” clear tubing and 5/8” clear tubing
      • Various lengths of this tubing must be cut to connect the components
      • To optimize the performance of the system, be sure to follow the recommendations for the lengths of tubing
      • Locate the outlet (discharge) water line on your Marvair air conditioner
        • Follow the water line, looking for a suitable place to install the CR330

    Diagram Parts List: (See Image Below)

    Number on Drawing
    Quantity
    Description
    12
    1
    CR330 condensate remover
    5
    1
    Strainer/filter with ½” FPT connections
    10
    1
    1/4” x 1/4” Check valve
    4
    1
    5/8” Barb x 1/2” FPT coupling
    3
    3
    Stainless Steel screw type hose clamp for 5/8” tubing
    7
    4
    Stainless Steel screw type hose clamp for 1/4” tubing
    8
    1
    2-1/2" x 1/4” ID clear tubing.
    11
    1
    7 ft x 1/4” ID clear tubing.
    1
    1
    1 ft x 5/8” ID clear tubing
    6
    1
    1/4” barb x 1/2” MPT adapter
    2
    1
    Hold down clamp for 5/8” tubing
    9
    2
    Hold down strap for 1/4” tubing
    13
    2
    Hold down strap for the CR330
    14
    1
    5/8” barb x 1/2” MPT fitting

    Click Here for an Installation Guide for this Product

    View Dometic's Air Conditioner Spec sheet

    Documentation available at the following links:

    View Dometic's Air Conditioner Spec sheet

    Customer Service Why Buy from Defender?
    null