    The Battery Sense / Power cable (FC01) is a battery harness with fuse for the Maretron DCM100 Direct Current DC Monitor.

    Features:

    • Provides battery sense and power
    • For use with DCM100 Direct Current (DC) Monitor (Sold Separately)
    • Length: 5 feet
    • Includes 1 amp Fuse

    Install the Battery Sense cable as follows:

    • Connect the yellow wire from one end of the cable to pin 6 (VSENS-) on the DCM100.
    • Connect the yellow wire from the other end of the cable to the negative terminal of the battery or DC source being monitored
      • Note: This may or may not be the same as the vessel ground this terminal either must be at the same voltage as pin 7 (VPWR-) or must have a positive voltage with respect to pin 7 (VPWR-)
    • Connect the red wire from the first end of the cable to pin 5 (VSENS+) on the DCM100
    • Connect the red wire from the other end of the cable to the positive terminal of the battery or DC source being monitored

    Install the Power cable as follows:

    • (FC01) is a white cable containing one red and one yellow wire
      • Note: This power cable is essential to operation since it provides power for the DCM100 to function
      • Install the DCM100 power cable as follows:
    • Connect the yellow wire from one end of the cable to pin 7(VPWR-) on the DCM100
      • Note: This terminal either must be at the same voltage as pin 6 (VSENS-) or must have a negative voltage with respect to pin 6 (VSENS-)
    • Connect the yellow wire from the other end of the cable to the vessel ground
    • Connect the red wire from the first end of the cable to pin 8(VPWR+) on the DCM100
    • Connect the red wire from the other end of the cable to a source of 9-32 VDC power
      • Note: This wire may nor may not be connected to the same place as the red wire from the Battery Sense cable
    Maretron Battery Voltage Sense / Power Cable
    34.49
    Status:    null In Stock

    The Battery Sense / Power cable (FC01) is a battery harness with fuse for the Maretron DCM100 Direct Current DC Monitor.

    Features:

    • Provides battery sense and power
    • For use with DCM100 Direct Current (DC) Monitor (Sold Separately)
    • Length: 5 feet
    • Includes 1 amp Fuse

    Install the Battery Sense cable as follows:

    • Connect the yellow wire from one end of the cable to pin 6 (VSENS-) on the DCM100.
    • Connect the yellow wire from the other end of the cable to the negative terminal of the battery or DC source being monitored
      • Note: This may or may not be the same as the vessel ground this terminal either must be at the same voltage as pin 7 (VPWR-) or must have a positive voltage with respect to pin 7 (VPWR-)
    • Connect the red wire from the first end of the cable to pin 5 (VSENS+) on the DCM100
    • Connect the red wire from the other end of the cable to the positive terminal of the battery or DC source being monitored

    Install the Power cable as follows:

    • (FC01) is a white cable containing one red and one yellow wire
      • Note: This power cable is essential to operation since it provides power for the DCM100 to function
      • Install the DCM100 power cable as follows:
    • Connect the yellow wire from one end of the cable to pin 7(VPWR-) on the DCM100
      • Note: This terminal either must be at the same voltage as pin 6 (VSENS-) or must have a negative voltage with respect to pin 6 (VSENS-)
    • Connect the yellow wire from the other end of the cable to the vessel ground
    • Connect the red wire from the first end of the cable to pin 8(VPWR+) on the DCM100
    • Connect the red wire from the other end of the cable to a source of 9-32 VDC power
      • Note: This wire may nor may not be connected to the same place as the red wire from the Battery Sense cable